Control of the Shunt Active Power Filter for Current Control
DOI:
https://doi.org/10.71701/e8s00n64Keywords:
Active power filter, Park transformation, phase-locked loop (PLL), Pulse width modulation (PWM), PI Controller, unbalanced and balanced loadAbstract
This paper presents a new simplified topology of current shunt active filter controller, that not require to measure active or reactive power of the load. For the proposed control Phase Locked Loop (PLL) is used a as filter voltage and an autotuning filter of current. The control method presented in this paper provides adequate compensation for non-ideal tension. The simulation results will be presented to verify the effectiveness of the proposed control technique.
Downloads
References
Abaali, H., Lamchich, M., & Raou, M. (2008). Shunt Power Active Filter Control under Non Ideal Voltages Conditions. International Journal of Electrical, Computer, Energetic, Electronic and Communication Engineering, 2 (10), 2427-2432.
Akagi, H., Hirokazu, E., & Aredes, M. (2007). Instantaneous Power Theory and Applications to Power Conditioning. EE.UU: Wiley-IEEE Press.
Apte, N., Bapat, V., & Jog, A. (2007). A Shunt Active Filter for Reactive Power Compensation and Harmonic Mitigation. 7th International Conference on Power Electronics, Daegu, Corea del Sur.
Azevedo, H., Ferreira, J., Martins, A., & Carvalho, A. (2003). Direct Current Control of an Active Power Filter for Harmonic Elimination, Power Factor Correction and Load Unbalancing Compensation. Porto: Faculty of Engineering of The University of Porto. Recuperado de https://repositorio-aberto.up.pt/bitstream/10216/202/2/24507.pdf
Singh, B., Al-Haddad, K., & Chandra, A. (1999). A Review of Active Filters for Power Quality Improvement, IEEE Transactions on Industrial Electronics, 46 (5), 960–971.
López, O. (2010). Filtro activo paralelo para compensación de factor de potencia y distorsión armónica en aplicaciones industriales (Tesis de maestría). Universidad Nacional de Colombia, Bogotá. Recuperado de https://core.ac.uk/ download/pdf/11052869.pdf?repositoryId=334
Pigazo, A. (2004). Método de control de filtros activos de potencia paralelo tolerante a perturbaciones de la tensión de red (Tesis doctoral). Universidad de Cantabria, Santander. Recuperado de http://www.tdx.cat/bitstream/ handle/10803/10632/0de8.APLprevio.pdf?sequence=1
Rashid, M. (Ed.). (2001). Power Electronics Handbook. Canadá: Academic Press.
Rodríguez, P. (2005). Aportaciones a los acondicionadores activos de corriente en derivación para redes trifásicas de cuatro hilos (Tesis doctoral). Universidad Politécnica de Cataluña, Barcelona.
Samet, B., Soydan, R., Ozgur, O., & Malabika, B. (2013). Control of the shunt Active Power Filter under non-ideal grid voltage and unbalanced load conditions. Power Engineering Conference (UPEC), (pp.1- 5). Dublin, Irlanda.
Núñez Zúñiga, T., Soto Lock, A., & Moreno Martínez, R. (2014). Filtro Activo de Potencia Bajo Diferentes Tipos de Carga. Electrónica - UNMSM, 15, 17-27. Recuperado de http://revistasinvestigacion.unmsm. edu.pe/index.php/electron/article/view/3987
Downloads
Published
Issue
Section
License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.